SPS Series Features

• 8 different Btu sizes and more than 60 different configurations to custom design your infrared heating system
• CSA design certified
• Available in natural and propane gas
• Optional elbows and corner reflectors
• Optional decorative grille
• Sidewall or through the roof venting
• Vented or indirect vented operation
•Includes 36" stainless steel gas connector


 

Push Through System
• Products of combustion are pushed through the combustion chamber
• No draft hoods, totally enclosed combustion chamber
• Blower motor totally enclosed in the burner box. Ideal for applications where minimal noise (less than 60 dB) is desired.
• Heavy duty permanently lubricated ball bearing, totally enclosed motor for maintenance-free operation
• 30 second pre-purge before ignition and 30 second post-purge after thermostat is satisfied
• Diaphragm air switch for proof of venting before gas flow and ignition

Gas Shut-Off Safety Control
• Burner inspection sight glass
• Step-opening redundant combination gas valve for quite ignition and added safety
• Inside or outside air for combustion
• Up to 25 ft. outside combustion air capability
• Standard outside combustion air intake
• Diagnostic Monitoring Light System

Burner System
• Heavy duty cast iron burner
• Reliable direct spark ignition systems and 100% gas shut-off safety control
• Burner inspection sight glass
• Step-opening redundant combination gas valve for quiet ignition and added safety
• Inside or outside air for combustion
• Up to 25 ft. outside combustion air capability
• Standard outside combustion air intake
• Diagnostic Monitoring Light System

Reflector System
• Highly efficient aluminum reflectors
• Individual reflectors can be rotated up to 45° to
direct heat where needed
• Optional end, corner, U-bend and side extension reflectors

Radiant Emitter Tube System
• 4” O.D. heat treated aluminized steel combustion chamber (10’ length)
• Standard highly emissive radiant tubes (10’ lengths)
• Optional aluminized steel radiant tubes (Tough Guy Option)
• 5 year limited warranty on all tubes
• Suitable for horizontal or angle mounting up to 45°
• Up to 25 feet sidewall vent capability

Go to top

 

Introducing TISSTM Tube Integrity Safety Shut-Off System

SunStar's patent pending innovative safety feature for positive pressure radiant tube heaters is called the “Tube Integrity Safety System” (TISS™).

In the unlikely event of a tube failure, TISS™ has been designed to automatically shut off the heater. The revolutionary TISS™ uses a simple principle to place an electrically insulated aluminum wire in tension above the reflector. Low voltage is then continuously passed along the wire in line with the gas control circuit. If heat levels increase due to heat exchanger failure, the wire melts and the safety circuit is broken, breaking the 24 volt circuit and shutting down the heater.

You may never know it is there, but it provides peace of mind.

Go to top

SPS Dimensions

Model
Total Tube Length
Overal Dimensions "L" (FT)
SPS (40)
10'
17'
SPS (40, 50, 75)
20'
22'
SPS (50, 75, 100, 125)
30'
32'
SPS (100,125, 150, 175)
40'
42'
SPS (125, 150, 175, 200)
50'
52'
SPS (150, 175, 200)
60'
62'
SPS (175, 200)
70'
72'

SPS-Bottom View

SPS-End View


Go to top

 

SPS Supply Requirements

Gas Type
Burner
Pressure
Supply Pressure
Voltage
Amps
Ingition
Type
MIN.
MAX.
 
 
  Natural
3.5" W.C.
5" W.C.
14" W.C.
120 VAC
60 Hz
2.4
Direct Spark
  Propane
10" W.C.
11" W.C.
14" W.C.

Go to top

SPS Minimum Mounting Heights

Model
Height at Horizontal
Height at 45° Angle
Model
Height at Horizontal
Height at 45° Angle
SPS 40
10 Ft.
9 Ft.
SPS 125
14 Ft.
13 Ft.
SPS 50
11 Ft.
10 Ft.
SPS 150
15 Ft.
14 Ft.
SPS 75
13 Ft.
12 Ft.
SPS 175
16 Ft.
15 Ft.
SPS 100
14 Ft.
13 Ft.
SPS 200
18 Ft.
16 Ft.
NOTES: Since straight tubes are always hotter at the burner end than at the exhaust end, always observe the minimum recommended mounting heights shown on the specification sheet for greatest human comfort. Use SPU series instead of SPS series for spot heating applications.

Go to top

SPS Clearances to Combustibles

Model No.
Side
Ceiling
Below
End
(45°) Front
(45°) Rear
SPS 50
27"
6"
40"
30"
48"
12"
SPS 75
27"
6"
60"
30"
48"
12"
SPS 100
66"
6"
80"
40"
66"
20"
SPS 125
66"
6"
101"
40"
66"
20"
SPS 150
84"
6"
106"
48"
84"
24"
SPS 175
84"
6"
106"
48"
84"
24"
SPS 200
84"
6"
106"
48"
84"
24"

When used indirect vented, clearance to ceiling from top of exhaust hood must be 12" on SPS 50, SPS 75 and 18" on SPS 100-SPS 200.